At 03:22 on June 29, 2019, Huang Li, a tank watcher, found that the dissolved oxygen of 208 cans for koilanin 2121-190602 was 27.2%, which was lower than the process range (process requirement ≥30%), at 03:31 The dissolved oxygen rises back into the process range for a total of 9 minutes. Afterwards, there were two similar situations where the dissolved oxygen was lower than the process range. At 05:32, the dissolved oxygen rose back into the process range, and the three times lasted a total of 29 minutes. <br><br>The root cause of this deviation is that there are few production batches for kolanin, the lack of actual operation experience by tank personnel, and the relevant SOP does not specifically describe the mid-early dissolved oxygen adjustment method, and cannot effectively guide the post operation, resulting in the operation process. The adjustment range of the medium dissolved oxygen flow rate is too large, and the pressure of the tank cannot be kept stable when the pressure is adjusted, which eventually causes the deviation. <br><br>The deviation occurred during 41-43h of the fermentation culture period, during which the oxygen demand of the cells began to weaken, and the stirring was running normally, the air flow rate was still within the process range (process range 200 ~ 700m3 / h), which could provide a certain amount of solvent Oxygen, short-term low dissolved oxygen causes less damage to the bacteria. 1) The results of the fermentation broth before and after the deviation (listed in the preliminary investigation) all meet the quality standards of teicoplanin intermediates; 2) The final result of the tank is: the culture period is 166h, the fermentation broth is brownish yellow, and the mycelium Aging, tending to autolysis, fermentation unit 7144.5μg / ml, reached the standard of the tank (period 130h-170h, tank conditions: fermentation broth is brownish yellow, mycelia aging, tend to autolysis, fermentation unit is not increasing or growing Slow, fermentation unit ≥6000μg / ml), so the deviation here has basically no effect on the product. <br><br>1. The conclusion obtained after a comprehensive investigation, revision H3-MPD-10325-02 "Operation Regulations of Teicoplanin Fermentation Posts" 03 edition, adding the method of adjusting dissolved oxygen in the early and middle stage of dissolved oxygen recovery of teicoplanin 1) .Once the dissolved oxygen rises to more than 60%, then adjust; 2). The flow rate of each adjustment is small (recommended not to exceed 50m3 / h); 3). When adjusting the flow rate, ensure that there is no obvious fluctuation in pressure (open the air valve while closing Exhaust valve).<br>2. Train all personnel in Building Y10 of Workshop 109 in the revised H3-MPD-10325-02 "Operation Regulations for Tiicoplanin Fermentation Posts", emphasizing the operating methods for the adjustment of dissolved oxygen in the early and mid-stage dissolved oxygen recovery of tiicoplanin, And use this deviated air flow operation as a counterexample to improve employees' awareness.
正在翻译中..