Fig. 7 compares the peak value of zero-sequence circulation before and after correction respectively, and the values in the figure are standardized based on VDCTs/8Lcm. Four hundred and fifty-one Because the lowest slope of zero-sequence circulating current in the vector combination of short vector and medium vector is 1, combined with the symmetry of the vector sequence in the switching period, the maximum value Izmax of zero-sequence circulating current can be optimized to VDCTs/8Lcm at the lowest in the staggered carrier frame.