On July 17, 2019, at 08:26, Zhang Wei, head of sodium freeze-dried production, viewed the 2017-190703 batch on the main interface of the D3003A freeze-drying machine computer. When the sodium sodium freeze-drying procedure of sistadine was found to be inconsistent with the eighth step (-5c, 0.28mbar, 9h) and the eighth step of the process requirement (-5C, 0.28mbar, 15h). <br><br>After the eighth step of the freeze-drying machine procedure was modified, it was not changed back in time, which was the direct cause of the deviation, and neither the operator nor the reviewer carefully checked the freeze-drying process, so that no abnormality was found in the freeze-drying process, which is the root cause of the deviation.<br><br>2017-190703 batch of sittatin sodium freeze-dried process production of the key process and sistatin sodium process procedures are not consistent, so according to non-conforming products for destruction treatment.<br>After the production of the 2017-190703 batch of satadine sodium freeze-dried process, the eighth step of the process (-5 degrees C, 0.28 mbar, 9h) has been changed back to the eighth step (-5 degrees C, 0.28 mbar, 15h), so it has no effect on the quality of the next batch of products.<br><br>1. Change the eighth step of the process (-5 degrees C, 0.28 mbar, 9h) to step 8 (-5 degrees C, 0.28 mbar, 15h) after the production of the 2017-190703 batch of sistatin sodium freeze-drying process and before the next batch of production.<br>2. To freeze-dried staff "H3-MPD-10318-15 sterile sitatria sodium freeze-dried post operating procedures (Y76E)" training, emphasizing the opening of freeze-dried process, to carefully check the freeze-drying process parameters.