Residential building ventilation purification IAQS software development and validation <br><br>Given the importance of indoor air quality of residential buildings and residential buildings for indoor PM2.5 concentrations forecasting, analysis and evaluation software is more scarce, user-friendly, simple operation residential building ventilation purification Software (IAQS ) was developed in this study, and software building thermal environment DeST (BAS) and ventilation (Ventplus) analysis module is calculated based to simulate and predict the different forms of ventilation purification ventilation purification strategies at room temperature, CO2 concentration, PM2.5 concentration and building heating energy consumption of air conditioning and ventilation purification energy consumption. <br>Natural ventilation is further an example, each room in a building and a room for two simulation object, comparison and verification between IAQS EnergyPlus software, results showed that: both the room for a building, and EnergyPlus used IAQS 1) the average relative deviation calculation results when the CO2 concentration by 7.0%, average relative deviation calculation results when PM2.5 concentrations by 11.0%; 2) for two rooms of the building, two software calculation results by the average CO2 concentration the relative deviation is 18.9%, average relative deviation calculation results when PM2.5 concentrations by 20.6%. Calculates a deviation between the two substantially within reasonable limits, IAQS software reliability of the results thus confirmed. <br>[Key words] residential building; ventilation purification; PM2.5 forecasting; IAQS software; contrast verification