At 14:57 on May 18, 2019, Luo Xingtu, the freeze-drying machine operator, heard the alarm sound of d3003a freeze-drying machine in the control room of y76e freeze-drying machine, and checked the main interface of d3003a freeze-drying machine computer. The alarm content was "al-lsl25004 - low liquid level alarm of silicone oil expansion tank", which caused the No.2 silicone oil pump (fp25020) to stop running. At 15:14, the silicone oil temperature (prb-tirc25039) rose to - 36.9 ℃, which was in progress The fourth step of 2017-190505 batch of cilastatin sodium freeze-drying process (- 40 ℃, 1H), exceeding the process requirements (- 40 ± 3 ℃).<br>The reason for the oil leakage is that the post personnel missed to check whether the connection between the inlet and outlet of the silicon oil electric heater (eh25035) and the screw and nut at the flange was loose, on the other hand, the screw thread was partially worn, resulting in incomplete sealing at this place.<br>1. This deviation has nothing to do with the tightness of the lyophilizer box, so it has no effect on the sterility of 2017-190505 batch of cilastatin sodium.<br>2. During the alarm, the freeze-drying procedure of cilastatin sodium runs to step 4, which is the last hour of the pre freezing stage, to ensure the freeze-drying of the material liquid (for freeze-dried products, if there is no freeze-drying in the pre freezing stage, there may be melting, collapse and other phenomena); the alarm lasts for about 1 hour from the occurrence of the alarm to the restoration of normal, which may cause the collapse of the properties of the freeze-dried powder, so It may affect the product properties and moisture; the batch of cilastatin sodium was freeze-dried on May 21, 2019, and no freezing collapse or melting was found during discharging. When the deviation occurs, the lyophilized liquid is at low temperature, and the stability of the material liquid is less likely to be affected; in addition, the whole process after step 4 runs according to the set process requirements, so the impurities of the product are basically not affected.<br>3. Conclusion: according to the evaluation in 4.1 and 4.2, the quality of 2017-190505 sterile cilastatin sodium may be at risk, and the water content, properties and impurities of this batch of finished products need to be tracked. Follow up the quality of finished products in the later stage.<br>1. Carry out "h3-tm-10235 version 03 freeze dryer system maintenance operation procedures" training for freeze dryer post personnel, with special emphasis on whether the tightness inspection of key parts is loose during daily maintenance.<br>2. Replace the screws and nuts at the flange connecting the inlet and outlet of the silicone oil electric heater (eh25035) and the pipeline.<br>3. 2017-190505 before the release of sterile cilastatin sodium, the front box of the lyophilizer was tested for tightness.<br>
正在翻译中..