Compare the hydraulic schematic diagram, check all ball valves, butterfly valves, etc., to ensure that all manual valves are in the correct open and closed positions; <br>compare the hydraulic schematic diagram, check that various valves, especially the one-way valves, are in the correct position and direction; <br>compare the hydraulic pressure Schematic diagram, check each pipeline to ensure that the pipeline connection is correct; <br>adjust the pressure of the overflow valve of the cooling and filtering circuit to the lowest pressure, respectively inching the motors D4 and D5 to ensure the steering and cooling of the 3KW motor, and the vane pump for filtering. Requires consistent steering. <br>(Note: Before leaving the factory, the pressure of the overflow valve has been adjusted properly. If it is not necessary, there is no need to adjust the pressure again, just make sure that the motor rotates in the correct direction)
正在翻译中..